Fire Sprinkler Hydraulic Calculation and Design Software.
Visa/MC/Amex/PayPal/Wire Transfer/Direct Deposit
Fire Sprinkler Hydraulics and Fire Protection Software
Visa/MC/Amex/PayPal/Wire Transfer/Direct Deposit


Download a DEMO
Order
Reports
Hydraulics & Fluid Mechanics
Submit Your Data & We Run the Calcs
Frequently Asked Questions
Contact Us

(800-845-9819) DISCOUNT PRICE ON IMMEDIATE PURCHASE (800-845-9819)
SOFTWARE PACKAGE
SOFTWARE DESCRIPTION
PRICE
Commercial 5.8 for Windows
Commercial & Industrial fire, foam & spray sprinklers per NFPA 13,15,16,231-C
US/Metric/User Manual.
Screens Reports Calc Specs Pipes Pump Tank Velocity PayPerCalc DOWNLOAD DEMO zip exe
$3000

Visa/MC/Amex/Wire Transfer/Direct Deposit
Residential 5.8 for Windows
Residential fire sprinklers per NFPA 13D, 13R, CRC 313.3
US/User Manual.
Screens Reports Calc Specs Pipes Pump Tank PayPerCalc
$3000

Visa/MC/Amex/Wire Transfer/Direct Deposit
StandPipe 5.2 for Windows
StandPipes & Private Hydrants per NFPA 14. Marinas & Boatyards per NFPA 303 US/Metric/User Manual.
Screens Reports Calc Specs Pipes PayPerCalc
$1500

Visa/MC/Amex/Wire Transfer/Direct Deposit
Hydrant Flow Test 6.0 for Windows
Hydrant Flow Test per NFPA 291 & AWWA M17
US/User Manual.
Screens Reports Calcs Maps Specs DOWNLOAD DEMO zip exe
$795

Visa/MC/Amex/Wire Transfer/Direct Deposit
Hydrant Flow Test 5.1 for Windows
Hydrant Flow Test per NFPA 291 & AWWA M17
US/User Manual.
Screens Reports Calcs Specs DOWNLOAD DEMO zip exe
$495

Visa/MC/Amex/Wire Transfer/Direct Deposit
Commercial 4.4 for Windows
Commercial & Industrial fire sprinklers per NFPA 13,231-C
US/Metric/User Manual.
Screens Reports Calc Specs Pipes DOWNLOAD DEMO zip exe
$1795
$1500
Visa/MC/Amex/Wire Transfer/Direct Deposit
Residential 4.4 for Windows
Residential occupancies per NFPA 13D, 13R, CRC 313.3 US/User Manual.
Screens Reports Calc Specs Pipes PayPerCalc
$1795
$1500
Visa/MC/Amex/Wire Transfer/Direct Deposit
StandPipe 4.4 for Windows
StandPipes & Private Hydrants per NFPA 14. Marinas and Boatyards per NFPA 303 US/Metric/User Manual.
Screens Reports Calc Specs Pipes PayPerCalc
$1000

Visa/MC/Amex/Wire Transfer/Direct Deposit
Commercial 2.5 for DOS.
Commercial & Industrial occupancies per NFPA 13,231-C
US/Metric/User Manual.
Screen Reports Specs Download Commercial 2.5 DEMO Demo
$895

Visa/MC/Amex/Wire Transfer/Direct Deposit
Residential 2.5 for DOS
Residential occupancies per NFPA 13D, 13R
US Units/User Manual.
Screen Reports Specs
$895

Visa/MC/Amex/Wire Transfer/Direct Deposit

Discount Price

The monthly discount price ( disc ) appears in the PRICE column directly below the ( retail ) price. This price only applies to an IMMEDIATE PURCHASE i.e. one completed on the same day that an offer is made to you by phone, email or fax. If you cannot complete the purchase on the same day contact us immediately for an extension. Discount prices are subject to change without notice.


The Booster Pump Dialog

Commercial 5.8 for Windows - Click for Details

Commercial 5.8 for Windows features an Advanced Pump Selection Dialog that automatically calculates the pump rated pressure and pump rated flow. It plots the pump curve and keeps track of important fire pump discharge and suction parameters. The Net Positive Suction Pressure Available is calculated using elevation pressure losses(Hz), underground piping friction losses (Hf) and fixed losses between the source and pump suction.


Hydrant Flow Test 6.0 for Windows

Hydrant Flow Test 6.0 Mapping Module - Click for Details
Hydrant Flow Test 6.0 GeoCoder - Click for Details

        Hydrant Flow Test 6.0 for Windows features dynamic spreadsheets for calculating and displaying the results of single or multiple hydrant flow tests. There is no limit on the number of flow test locations and outlets flowed. The dynamic graph responds immediately to changes in all major hydrant flow test parameters. The graph displays extrapolated flow at 0 psi, 20 psi and other user defined values of pressure. The Mapping Module plots color coded Class AA, A & B hydrant markers by street address or GPS coordinates.
        The Hydrant Flow Test 6.0 Geocoder translates street addresses to GPS coordinates. The Geocoder Utility in the Mapping Module features a marker tool that can be dragged and dropped on the map to determine precise GPS coordinates for any place on earth. Reports, graphs and maps can be printed for individual or multiple hydrant flow tests. Flow test parameters and results are displayed in a scrollable Summary spreadsheet. The spreadsheet can be sorted and searched for results matching file name, hydrant, location, date, static, residual, flow and other variables. Copy and Paste hydrant flow test summary results to Microsoft Excel.

Controls

HYDRONICS features impressive state-of-the-art custom controls that put you in charge of all the data entry and editing requirements for your Fire Sprinker Hydraulic calculations. It features pull down menus and scrollable spreadsheets linked to button bars for copy, paste, repeat, replace, insert and delete operations on multiple or single blocks of nodes and pipes. Typical values can be easily entered for multiple nodes and pipes. Click a button bar to repeat lines or columns in the spreadsheet. Clicking on the printer icon sends input or output data to the printer. Losses for meters and backflow devices are entered in psi. The system can be balanced for a minimum end-head flow or pressure. A single mouse click checks for errors, starts the calculation and displays the output. HYDRONICS uses finite element analysis in conjunction with the Newton-Raphson and LaGuerre algorithms for quickly and accurately balancing any fire sprinkler system configuration.


Utilities

  • Tank Flow Utility - allows users to modify or add to the built-in pipe diameters, fitting symbols, symbol descriptors and equivalent lengths.
  • Pipe Table Editor - allows users to modify or add to the built-in pipe diameters, fitting symbols, symbol descriptors and equivalent lengths.


Velocity Analyzer

Commercial 5.8 for Windows - Velocity Analyzer Utility

         The Velocity Analyzer Utility calculates the Reynolds Number, a key measure of fluid turbulence and non-laminar flow. The Reynolds Number is a function of pipe diameter(in), flow(gpm) and kinematic viscosity(Sq-Ft/sec). The Velocity Analyzer uses the Reynolds Number and measures of pipe roughness to calculate Moody's f and pipe friction loss(psi/ft) using the Darcy-Weisbach equation. The Velocity Analyzer also displays pipe friction loss using the Hazen-Williams equation.


Tank Flow

Commercial 5.8 for Windows - Tank Flow Utility

         The Tank Flow Utility is used for estimating the total pressure, velocity and flow from a water tank. The total pressure estimate takes into account vapor pressure, atmospheric pressure and water pressure. Vapor pressure is related to water temperature selected from a drop down list box. Atmospheric pressure varies with the value entered for elevation relative to sea level. Water pressure depends on the value entered for the tank water level relative to the spout centerline. The flow depends on the values entered for spout diameter and a coefficient for entry and exit losses. These parameters play an important role in matching tanks with fire pumps.


Pipe Table Editor

Commercial 5.8 for Windows - Pipe Table Editor

         A single key press or mouse click gives you access to 7 different kinds of sprinkler piping. There are over 60 built-in diameters for Steel, XL, Copper, Dynaflow, CPVC, PVC and Ductile Iron. Pipe sizes may be entered as nominal (1, 1.25,1.5, ...) or actual (1, 1.049, 1.380,...) diameters. There are 7 different fitting symbols. Multiple fittings are easily described e.g. 4E3T means four elbows and three tees. Fittings may also be entered as total equivalent lengths of pipe. Use the Pipe Table Editor and enter your own unique values for diameters, fitting symbols and fitting lengths.


Analysis

HYDRONICS provides you with immediate and comprehensive summaries of the hydraulic calculation output that can be viewed on your screen or sent to the printer. You can easily keep track of the friction loss, flow and velocity for every pipe in your sprinkler system.


SAMPLE SUBMITTAL REPORTS

Tree System
Compound Grid
StandPipe Calc
Residential 1-Head Calc
Residential 2-Head Calc
Hydrant Flow Test

CREATE REPORTS IN ADOBE PDF ADOBE PDF Reports

Commercial 5.8 for Windows - Save PDF File

         Create genuine Adobe PDF NFPA-Style reports from Commercial 5.8 and Residential 5.8 that can be viewed using Adobe Reader and sent to any email address.


E-Mail
CONTACT US
E-Mail

Ph: 800-845-9819 Fx: 510-474-1438

PHONE
SERVICE
REMARKS
800-845-9819
DEMO's and Purchases
Order Toll Free
510-474-1438
Secure Fax
Credit Card


Copyright 2013 Hydronics Engineering. All rights reserved.
34119 Fremont Bl, Suite 609, Fremont, CA 94555, USA.
Ph: (800) 845-9819 / Fx: (510) 474-1438
sales@hydronicseng.com